Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › MapCheck2 (w/MapPhan) Eclipse model for VMAT QA
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: Emcp
New Today: 0
New Yesterday: 0
Overall: 981

People Online:
Members: 0
Visitors: 37
Total: 37
Who Is Where:
 Visitors:
01: Downloads
02: Downloads
03: Downloads
04: Downloads
05: Downloads
06: External downloads
07: Downloads
08: Downloads
09: Downloads
10: Home
11: External downloads
12: External downloads
13: Downloads
14: Downloads
15: Downloads
16: External downloads
17: External downloads
18: Downloads
19: External downloads
20: External downloads
21: External downloads
22: Downloads
23: External downloads
24: Home
25: Downloads
26: External downloads
27: Downloads
28: Downloads
29: External downloads
30: Downloads
31: Home
32: Downloads
33: External downloads
34: External downloads
35: Downloads
36: Downloads
37: Home

Staff Online:

No staff members are online!
MapCheck2 (w/MapPhan) Eclipse model for VMAT QA
Main | Details | Download Now | History | Statistics

Add your mirror to this download

Category Treatment Planning
Submitted by antoneagle
Author's Name
Anton Eagle
Distributed with custom license file? No
Published
Fri May 27, 2016 8:00 pm

This is the MapCheck2 (w/MapPhan) model we use here at North Star Lodge Cancer Center, for VMAT QA. This is a 351 slice CT, with a structure set containing 11 structures.

We are only overriding 3 structure densities. The Top_Plate = 600 HU, the Diode_Plane = -200 HU, and the Bottom_Plate = 0 HU.

*** This dataset should not be expected to work for you clinic without adjustment. ***

This is the testing procedure we used here at North Star Lodge Cancer Center to dial-in the HU values for the density overrides.
This procedure is intended for the MapCheck2 device with the MapPhan solid water build-up sleave.


Setup the MapPhan as normal, at the end of your couch. Set the scored-marks on the MapPhan so that the diode plane is at your linac's isocenter.

Obtain MapCheck2 meassurements for a 10x10 cm field in the AP direction, the PA direction, and shoot a 10x10 cm field as a full arc. Do this for each energy.

For each energy, make note of the relative readings between the AP, PA, and Arc (using the central diode value).


In Eclipse... setup the same fields as described above, and calc the QA plans. Compare the realative readings for AP, PA, and Arc in Eclipse to the relative readings as measured above. Also, ensure that the dose delivered to the central diode for the AP field in Eclipse matches your TPR(d=5,fs=10) value in your beam data... this ensures that your dose calibration will be correct.


Tweak the HUs as necessary to get the relative ratio of the fields in Eclipse to match the actual meassurements, while keeping the dose to the central diode of the AP field matching your beam data.
Rating Not rated
Popularity 3/5: Average
Downloads 434
Page views 4128

Download Now
Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy