Main Menu
|
|
Home Members options Search |
|
|
|
|
User Info
|
|
|
|
|
|
|
Downloads › Linear Accelerators
Main | Search | Add Download |
New Downloads |
Random
Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.
Varian MLC test shapes |
|
Rating:  |
Popularity:  |
Published: Mon Jun 12, 2006 8:31 pm |
|
 |
Varian MLC square fields and closed fields for 52 and 120 leaf MLCs, useful for commissioning and light/radiation field measurements. |
Version 1.0 |
|
Varian EDW Data |
|
Rating:  |
Popularity:  |
Published: Sat Jan 06, 2007 10:03 am |
|
 |
This is a spreadsheet compilation of data sent to me. The data is presented as I recieved it, except for some formatting fixes for printing. I claim no credit for clever work nor accept responsibility for accuracy. We should all be grateful for the kindes |
|
|
Varian DynaLog File Anonymizer |
|
Rating:  |
Popularity:  |
Updated: Wed Aug 10, 2011 6:59 am |
|
 |
Program to automatically anonymize Varian DynaLog files. |
Version 1.01 |
|
TG51 Calibration |
|
Rating:  |
Popularity:  |
Published: Wed May 26, 2010 4:14 pm |
|
 |
TG-51 Calibration Workbook |
Version 3.2.2 |
|
TG-142 Physics QA Checklist |
|
Rating:  |
Popularity:  |
Published: Tue May 25, 2010 6:31 pm |
|
 |
This EXCEL spreadsheet copies all tables in Klein et al's TG-142 paper of September 2009. |
|
|
Sample iComCAT files for NCS report 24 |
|
Rating:  |
Popularity:  |
Published: Fri Oct 02, 2015 11:33 am |
|
 |
A sample of a few iComCAT files used as part of VMAT commissioning for an Elekta VersaHD following NCS report 24. |
|
|
Pinnacle_Script_for_Naming_Beams |
|
Rating:  |
Popularity:  |
Published: Fri Oct 08, 2010 10:11 am |
|
 |
This Pinnacle Script will rename a radiation beam based on the angle of incidence relative to the patient. The .txt extension on the file can be changed to .Script. |
|
|
Pinnacle_Script_for_Naming_All_Beams |
|
Rating:  |
Popularity:  |
Published: Fri Oct 08, 2010 10:12 am |
|
 |
This Pinnacle Script is to be used with NameBeam.Script (Pinnacle_Script_for_Naming_Beams), and will change the name of all the radiation beams in one trial to reflect the angle of incidence relative to the patient. |
|
|
Patient Gantry Collision Check |
|
Rating:  |
Popularity:  |
Published: Mon Jul 23, 2012 12:57 pm |
|
 |
A macro enabled excel spreadsheet to check for patient gantry collision when planning SBRTs or RapidArcs. Gantry and couch data was measured on a Varian Trilogy. |
Version 1.0 |
|
MU Calculation Spreadsheet for Linac |
|
Rating:  |
Popularity:  |
Published: Mon Feb 25, 2008 12:29 pm |
|
 |
Just a sample spreadsheet to compute or verify your TPS MU computation for 6 MV and 15 MV photons. |
|
|
Monthly calibration form |
|
Rating:  |
Popularity:  |
Updated: Thu Jun 15, 2006 9:20 pm |
|
 |
Simple Excel sheet for monthly calibration, PDD, and linearity tests for SSD calibrations. Ppol is not included. |
Version 1.01 |
|
Modified Winston-Lutz Test for IGRT Setups |
|
Rating:  |
Popularity:  |
Updated: Wed Apr 13, 2011 6:32 pm |
|
 |
Brief document describing the clinical implementation of a modified Winston-Lutz test. This test measures IGRT system end-to-end positioning accuracy with a precision of ~0.1 mm. It can be performed in less than 5 minutes. |
Version 1.1 |
|
Matlab script for generating Elekta Agility iCom files |
|
Rating:  |
Popularity:  |
Published: Fri Jul 26, 2013 11:08 am |
|
 |
Contains function write_rectangular_efs() will generates an iCom file for an arbitrary rectangular field. Function call_write_efs() illustrates its usage. Scripts are for Agility model only, but could be modified for other machines. |
|
|
|