Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › MapCheck2 (w/MapPhan) Eclipse model for VMAT QA
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: Nahuel
New Today: 0
New Yesterday: 1
Overall: 991

People Online:
Members: 0
Visitors: 57
Total: 57
Who Is Where:
 Visitors:
01: External downloads
02: Downloads
03: External downloads
04: External downloads
05: External downloads
06: Downloads
07: Home
08: Downloads
09: Downloads
10: External downloads
11: Downloads
12: Downloads
13: External downloads
14: External downloads
15: Downloads
16: External downloads
17: Home
18: External downloads
19: Home
20: External downloads
21: Downloads
22: Downloads
23: External downloads
24: Downloads
25: External downloads
26: Downloads
27: External downloads
28: Downloads
29: External downloads
30: Downloads
31: Downloads
32: External downloads
33: Downloads
34: External downloads
35: Downloads
36: Downloads
37: Downloads
38: External downloads
39: Downloads
40: Downloads
41: Home
42: Downloads
43: External downloads
44: Downloads
45: My Account
46: Downloads
47: External downloads
48: External downloads
49: Home
50: Downloads
51: Home
52: External downloads
53: Downloads
54: Home
55: External downloads
56: Downloads
57: Downloads

Staff Online:

No staff members are online!
MapCheck2 (w/MapPhan) Eclipse model for VMAT QA
Main | Details | Download Now | History | Statistics

Add your mirror to this download

Category Treatment Planning
Submitted by antoneagle
Author's Name
Anton Eagle
Distributed with custom license file? No
Published
Fri May 27, 2016 8:00 pm

This is the MapCheck2 (w/MapPhan) model we use here at North Star Lodge Cancer Center, for VMAT QA. This is a 351 slice CT, with a structure set containing 11 structures.

We are only overriding 3 structure densities. The Top_Plate = 600 HU, the Diode_Plane = -200 HU, and the Bottom_Plate = 0 HU.

*** This dataset should not be expected to work for you clinic without adjustment. ***

This is the testing procedure we used here at North Star Lodge Cancer Center to dial-in the HU values for the density overrides.
This procedure is intended for the MapCheck2 device with the MapPhan solid water build-up sleave.


Setup the MapPhan as normal, at the end of your couch. Set the scored-marks on the MapPhan so that the diode plane is at your linac's isocenter.

Obtain MapCheck2 meassurements for a 10x10 cm field in the AP direction, the PA direction, and shoot a 10x10 cm field as a full arc. Do this for each energy.

For each energy, make note of the relative readings between the AP, PA, and Arc (using the central diode value).


In Eclipse... setup the same fields as described above, and calc the QA plans. Compare the realative readings for AP, PA, and Arc in Eclipse to the relative readings as measured above. Also, ensure that the dose delivered to the central diode for the AP field in Eclipse matches your TPR(d=5,fs=10) value in your beam data... this ensures that your dose calibration will be correct.


Tweak the HUs as necessary to get the relative ratio of the fields in Eclipse to match the actual meassurements, while keeping the dose to the central diode of the AP field matching your beam data.
Rating Not rated
Popularity 2/5: Slightly below average
Downloads 436
Page views 4911

Download Now
Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy