Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Correction for PET-CT image registration in Pinnacle (7.6 & 8.0)
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: garypender
New Today: 0
New Yesterday: 0
Overall: 979

People Online:
Members: 0
Visitors: 25
Total: 25
Who Is Where:
 Visitors:
01: Downloads
02: Downloads
03: Downloads
04: Downloads
05: External downloads
06: Downloads
07: Downloads
08: Home
09: External downloads
10: Home
11: External downloads
12: Downloads
13: Downloads
14: External downloads
15: Downloads
16: Downloads
17: Downloads
18: Downloads
19: Downloads
20: Home
21: Downloads
22: Downloads
23: Downloads
24: External downloads
25: Downloads

Staff Online:

No staff members are online!
Correction for PET-CT image registration in Pinnacle (7.6 & 8.0)
Main | Details | Download Now | History | Statistics

Add your mirror to this download

Category Treatment Planning
Submitted by jhowe
Author's Name
Jonathan Howe
Version 1.0
Distributed with custom license file? No
Published
Mon May 24, 2010 3:52 pm

Instructions to correct for image registration offset when using the "copy transformation" function in Pinnacle.

Following successful registration of treatment planning CT with the CT from a PET study, using the "copy transformation" function of Pinnacle for the PET registration does not always provide the correct image registration of the PET. These instructions show how to correct for this problem by adding a shift to the registration parameters equal to the difference in the field-of-view of the datasets.
Rating Not rated
Popularity 1/5: Not popular
Downloads 336
Page views 3857

Download Now
Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.