Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Linear Accelerators
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: Aswathiraj
New Today: 0
New Yesterday: 0
Overall: 996

People Online:
Members: 0
Visitors: 55
Total: 55
Who Is Where:
 Visitors:
01: External downloads
02: Downloads
03: Home
04: External downloads
05: Downloads
06: Downloads
07: Downloads
08: Downloads
09: External downloads
10: External downloads
11: Home
12: My Account
13: Home
14: Downloads
15: Downloads
16: External downloads
17: External downloads
18: Home
19: External downloads
20: External downloads
21: External downloads
22: Downloads
23: Downloads
24: Downloads
25: External downloads
26: Downloads
27: Downloads
28: Downloads
29: Downloads
30: External downloads
31: My Account
32: Home
33: Downloads
34: Downloads
35: Downloads
36: Home
37: Home
38: Downloads
39: Downloads
40: External downloads
41: Downloads
42: Downloads
43: Downloads
44: Downloads
45: Downloads
46: Downloads
47: Home
48: Downloads
49: Downloads
50: Downloads
51: External downloads
52: Downloads
53: Downloads
54: Downloads
55: External downloads

Staff Online:

No staff members are online!
Downloads › Linear Accelerators

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.

 IMRT QA scripts for creating phantom plan (Pinnacle 8.0m)
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Mon Sep 20, 2010 11:08 am
Download Now
Pinnacle (ver 8.0m) scripts for expediting IMRT QA
Submitted by: vjeevan Homepage 1 review

 Imager Position Calculator (Varian Linacs)
Rating: Not rated Popularity: 2/5: Slightly below average Published: Mon Oct 15, 2018 4:15 pm
Download Now
Calculates optimal imager panel positions for a Varian linear accelerator, based on field size, collimator rotation and vertical imager position.
Submitted by: anmcgrath Homepage 0 reviews

 High energy linac shielding report
No screenshot
Rating: Good Popularity: 3/5: Average Published: Fri Oct 19, 2007 2:35 pm
Download Now
This is a shielding report for a new high energy (6/23 MV) installation, with calculations based on NCRP 151.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 Fast Real Time Calibration of Varian Linacs
No screenshot
Rating: Very good Popularity: 2/5: Slightly below average Published: Sat Jul 26, 2008 12:54 pm
Download Now
Fast Real Time Calibration of Varian Linacs from 2008 AAPM poster session SU-GG-T-208.
No voltmeter required. +/-0.2% accuracy in a few minutes.
Please see warnings.
Varian's method requires a voltmeter. This method does not:
Submitted by: kchu2 Homepage 1 review

 EGS_Window in Matlab
Rating: Good Popularity: 3/5: Average Published: Fri Aug 10, 2012 12:05 pm
Download Now
EGS_WINDOWS is a matlab version of the EGS_WINDOW code (that was developed and distributed for Linux systems).

USAGE: EGS_WINDOWS('*.egsgeom','*.egsgph')
EXAMPLE: For one of the BEAMnrc examples EX10MeVe:
EGS_WINDOWS('EX10MeVe.egsgeom','EX10MeVe.e
Version 1
Submitted by: bakhtiari Homepage 1 review

 Data Comparison of 10 Varian LINACs in North America
No screenshot
Rating: Good Popularity: 3/5: Average Published: Sat Jul 31, 2010 4:55 am
Download Now
Off axis ratio from Beam Profiles can be matched by fine adjustments of PDD. Data from 10 different Varian LINACs were compared. Output factors and Wedge factors were within 1% if measured the same way. Data was also compared to Varian's Golden Beam Data.
Submitted by: kchu2 Homepage 1 review

 Daily Warm-Up Check for Linacs
No screenshot
Rating: Below average Popularity: 2/5: Slightly below average Published: Fri Apr 17, 2009 11:56 am
Download Now
An MS EXCEL based daily log for monitoring the output of linear accelerators using a 5 point monitor chamber.
Submitted by: rbenson Homepage 1 review

 Annual report
No screenshot
Rating: Good Popularity: 4/5: Popular Published: Mon Jun 12, 2006 8:27 pm
Download Now
Annual QA report for a Varian.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 A Practical Guide to TG-142 QA
Rating: Very good Popularity: 5/5: Very popular Published: Tue Feb 14, 2012 10:39 pm
Download Now
This is a Word document and XLS file designed to assist clinical physicists with implementing AAPM TG-142 recommendations for linear accelerator QA. It provides examples of tests that can be performed to fulfill TG-142’s recommendations.
Version 1.0
Editor's Pick Submitted by: jrjones Homepage 1 review

Page: Previous  1, 2

Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy