Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Linear Accelerators
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: Tuhandes
New Today: 0
New Yesterday: 0
Overall: 1000

People Online:
Members: 0
Visitors: 55
Total: 55
Who Is Where:
 Visitors:
01: External downloads
02: Downloads
03: Home
04: External downloads
05: Home
06: External downloads
07: External downloads
08: Downloads
09: External downloads
10: Downloads
11: Home
12: Downloads
13: Downloads
14: Downloads
15: Downloads
16: Downloads
17: External downloads
18: External downloads
19: External downloads
20: Downloads
21: Home
22: External downloads
23: External downloads
24: External downloads
25: My Account
26: Downloads
27: Downloads
28: Downloads
29: External downloads
30: External downloads
31: Home
32: Downloads
33: Downloads
34: External downloads
35: External downloads
36: Downloads
37: Downloads
38: External downloads
39: Downloads
40: Home
41: Downloads
42: External downloads
43: External downloads
44: Downloads
45: External downloads
46: Downloads
47: Downloads
48: External downloads
49: Downloads
50: External downloads
51: External downloads
52: Downloads
53: Home
54: External downloads
55: Home

Staff Online:

No staff members are online!
Downloads › Linear Accelerators

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.

 IMRT QA scripts for creating phantom plan (Pinnacle 8.0m)
No screenshot
Rating: Good Popularity: 1/5: Not popular Published: Mon Sep 20, 2010 11:08 am
Download Now
Pinnacle (ver 8.0m) scripts for expediting IMRT QA
Submitted by: vjeevan Homepage 1 review

 Imager Position Calculator (Varian Linacs)
Rating: Not rated Popularity: 1/5: Not popular Published: Mon Oct 15, 2018 4:15 pm
Download Now
Calculates optimal imager panel positions for a Varian linear accelerator, based on field size, collimator rotation and vertical imager position.
Submitted by: anmcgrath Homepage 0 reviews

 High energy linac shielding report
No screenshot
Rating: Good Popularity: 3/5: Average Published: Fri Oct 19, 2007 2:35 pm
Download Now
This is a shielding report for a new high energy (6/23 MV) installation, with calculations based on NCRP 151.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 Fast Real Time Calibration of Varian Linacs
No screenshot
Rating: Very good Popularity: 2/5: Slightly below average Published: Sat Jul 26, 2008 12:54 pm
Download Now
Fast Real Time Calibration of Varian Linacs from 2008 AAPM poster session SU-GG-T-208.
No voltmeter required. +/-0.2% accuracy in a few minutes.
Please see warnings.
Varian's method requires a voltmeter. This method does not:
Submitted by: kchu2 Homepage 1 review

 EGS_Window in Matlab
Rating: Good Popularity: 2/5: Slightly below average Published: Fri Aug 10, 2012 12:05 pm
Download Now
EGS_WINDOWS is a matlab version of the EGS_WINDOW code (that was developed and distributed for Linux systems).

USAGE: EGS_WINDOWS('*.egsgeom','*.egsgph')
EXAMPLE: For one of the BEAMnrc examples EX10MeVe:
EGS_WINDOWS('EX10MeVe.egsgeom','EX10MeVe.e
Version 1
Submitted by: bakhtiari Homepage 1 review

 Data Comparison of 10 Varian LINACs in North America
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Sat Jul 31, 2010 4:55 am
Download Now
Off axis ratio from Beam Profiles can be matched by fine adjustments of PDD. Data from 10 different Varian LINACs were compared. Output factors and Wedge factors were within 1% if measured the same way. Data was also compared to Varian's Golden Beam Data.
Submitted by: kchu2 Homepage 1 review

 Daily Warm-Up Check for Linacs
No screenshot
Rating: Below average Popularity: 1/5: Not popular Published: Fri Apr 17, 2009 11:56 am
Download Now
An MS EXCEL based daily log for monitoring the output of linear accelerators using a 5 point monitor chamber.
Submitted by: rbenson Homepage 1 review

 Annual report
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Mon Jun 12, 2006 8:27 pm
Download Now
Annual QA report for a Varian.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 A Practical Guide to TG-142 QA
Rating: Very good Popularity: 5/5: Very popular Published: Tue Feb 14, 2012 10:39 pm
Download Now
This is a Word document and XLS file designed to assist clinical physicists with implementing AAPM TG-142 recommendations for linear accelerator QA. It provides examples of tests that can be performed to fulfill TG-142’s recommendations.
Version 1.0
Editor's Pick Submitted by: jrjones Homepage 1 review