Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Linear Accelerators
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: dingl
New Today: 0
New Yesterday: 0
Overall: 954

People Online:
Members: 0
Visitors: 37
Total: 37
Who Is Where:
 Visitors:
01: Downloads
02: Home
03: Downloads
04: Downloads
05: Downloads
06: Downloads
07: Downloads
08: Downloads
09: External downloads
10: Downloads
11: Downloads
12: Downloads
13: Downloads
14: Downloads
15: External downloads
16: Downloads
17: External downloads
18: Downloads
19: Downloads
20: Downloads
21: Downloads
22: External downloads
23: External downloads
24: Downloads
25: Downloads
26: Downloads
27: Downloads
28: Downloads
29: Downloads
30: Downloads
31: Downloads
32: Downloads
33: Downloads
34: Downloads
35: External downloads
36: FAQs
37: Downloads

Staff Online:

No staff members are online!
Downloads › Linear Accelerators

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.

 Varian DynaLog File Anonymizer
Rating: Not rated Popularity: 3/5: Average Updated: Wed Aug 10, 2011 6:59 am
Download Now
Program to automatically anonymize Varian DynaLog files.
Version 1.01
Submitted by: nathanchildress Homepage 0 reviews

 Modified Winston-Lutz Test for IGRT Setups
Rating: Not rated Popularity: 3/5: Average Updated: Wed Apr 13, 2011 6:32 pm
Download Now
Brief document describing the clinical implementation of a modified Winston-Lutz test. This test measures IGRT system end-to-end positioning accuracy with a precision of ~0.1 mm. It can be performed in less than 5 minutes.
Version 1.1
Submitted by: nathanchildress Homepage 0 reviews

 TG 51 Calculator V2.1
Rating: Not rated Popularity: 3/5: Average Updated: Wed Sep 13, 2006 1:40 am
Download Now
TG 51 Calculator
Version 2.1
Submitted by: ryankou Homepage 0 reviews

 Monthly calibration form
Rating: Not rated Popularity: 3/5: Average Updated: Thu Jun 15, 2006 9:20 pm
Download Now
Simple Excel sheet for monthly calibration, PDD, and linearity tests for SSD calibrations. Ppol is not included.
Version 1.01
Editor's Pick Submitted by: nathanchildress Homepage 0 reviews

 Survey of SRS Cone Factors
No screenshot
Rating: Below average Popularity: 2/5: Slightly below average Published: Tue Jan 06, 2015 1:06 pm
Download Now
Survey of SRS Cone Factors by Rick Peters
Submitted by: scottdube Homepage 1 review

 Matlab script for generating Elekta Agility iCom files
Rating: Rubbish Popularity: 3/5: Average Published: Fri Jul 26, 2013 11:08 am
Download Now
Contains function write_rectangular_efs() will generates an iCom file for an arbitrary rectangular field. Function call_write_efs() illustrates its usage. Scripts are for Agility model only, but could be modified for other machines.
Submitted by: cejones Homepage 1 review

 A Practical Guide to TG-142 QA
Rating: Very good Popularity: 5/5: Very popular Published: Tue Feb 14, 2012 10:39 pm
Download Now
This is a Word document and XLS file designed to assist clinical physicists with implementing AAPM TG-142 recommendations for linear accelerator QA. It provides examples of tests that can be performed to fulfill TG-142’s recommendations.
Version 1.0
Editor's Pick Submitted by: jrjones Homepage 1 review

 Annual report
No screenshot
Rating: Good Popularity: 3/5: Average Published: Mon Jun 12, 2006 8:27 pm
Download Now
Annual QA report for a Varian.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 Daily Warm-Up Check for Linacs
No screenshot
Rating: Below average Popularity: 2/5: Slightly below average Published: Fri Apr 17, 2009 11:56 am
Download Now
An MS EXCEL based daily log for monitoring the output of linear accelerators using a 5 point monitor chamber.
Submitted by: rbenson Homepage 1 review

 Data Comparison of 10 Varian LINACs in North America
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Sat Jul 31, 2010 4:55 am
Download Now
Off axis ratio from Beam Profiles can be matched by fine adjustments of PDD. Data from 10 different Varian LINACs were compared. Output factors and Wedge factors were within 1% if measured the same way. Data was also compared to Varian's Golden Beam Data.
Submitted by: kchu2 Homepage 1 review

 EGS_Window in Matlab
Rating: Good Popularity: 3/5: Average Published: Fri Aug 10, 2012 12:05 pm
Download Now
EGS_WINDOWS is a matlab version of the EGS_WINDOW code (that was developed and distributed for Linux systems).

USAGE: EGS_WINDOWS('*.egsgeom','*.egsgph')
EXAMPLE: For one of the BEAMnrc examples EX10MeVe:
EGS_WINDOWS('EX10MeVe.egsgeom','EX10MeVe.e
Version 1
Submitted by: bakhtiari Homepage 1 review

 Fast Real Time Calibration of Varian Linacs
No screenshot
Rating: Very good Popularity: 3/5: Average Published: Sat Jul 26, 2008 12:54 pm
Download Now
Fast Real Time Calibration of Varian Linacs from 2008 AAPM poster session SU-GG-T-208.
No voltmeter required. +/-0.2% accuracy in a few minutes.
Please see warnings.
Varian's method requires a voltmeter. This method does not:
Submitted by: kchu2 Homepage 1 review

 High energy linac shielding report
No screenshot
Rating: Good Popularity: 3/5: Average Published: Fri Oct 19, 2007 2:35 pm
Download Now
This is a shielding report for a new high energy (6/23 MV) installation, with calculations based on NCRP 151.
Version 1.0
Submitted by: nathanchildress Homepage 1 review

 IMRT QA scripts for creating phantom plan (Pinnacle 8.0m)
No screenshot
Rating: Good Popularity: 2/5: Slightly below average Published: Mon Sep 20, 2010 11:08 am
Download Now
Pinnacle (ver 8.0m) scripts for expediting IMRT QA
Submitted by: vjeevan Homepage 1 review

 MU Calculation Spreadsheet for Linac
Rating: Not rated Popularity: 2/5: Slightly below average Published: Mon Feb 25, 2008 12:29 pm
Download Now
Just a sample spreadsheet to compute or verify your TPS MU computation for 6 MV and 15 MV photons.
Submitted by: dayanloria Homepage 0 reviews

 Varian MLC test shapes
No screenshot
Rating: Not rated Popularity: 3/5: Average Published: Mon Jun 12, 2006 8:31 pm
Download Now
Varian MLC square fields and closed fields for 52 and 120 leaf MLCs, useful for commissioning and light/radiation field measurements.
Version 1.0
Submitted by: nathanchildress Homepage 0 reviews

 Radiotherapy equipment specifications
No screenshot
Rating: Not rated Popularity: 3/5: Average Published: Tue Nov 07, 2006 1:26 pm
Download Now
Radiotherapy equipment specifications, including evaluation criteria.
Submitted by: AdovR Homepage 0 reviews

 Varian EDW Data
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Sat Jan 06, 2007 10:03 am
Download Now
This is a spreadsheet compilation of data sent to me. The data is presented as I recieved it, except for some formatting fixes for printing. I claim no credit for clever work nor accept responsibility for accuracy. We should all be grateful for the kindes
Submitted by: RadPhysChuck Homepage 0 reviews

 Radiation warning signs (Word files)
Rating: Not rated Popularity: 2/5: Slightly below average Published: Thu Aug 14, 2008 6:28 pm
Download Now
Radiation warning signs in editable Microsoft Word documents.
Version 1.0
Submitted by: nathanchildress Homepage 0 reviews

 TG-142 Physics QA Checklist
No screenshot
Rating: Not rated Popularity: 3/5: Average Published: Tue May 25, 2010 6:31 pm
Download Now
This EXCEL spreadsheet copies all tables in Klein et al's TG-142 paper of September 2009.
Submitted by: rbenson Homepage 0 reviews

Page: 1, 2  Next

Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.