Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Category: Linear Accelerators
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: aabuali
New Today: 0
New Yesterday: 0
Overall: 1026

People Online:
Members: 0
Visitors: 76
Total: 76
Who Is Where:
 Visitors:
01: Home
02: Home
03: Downloads
04: Home
05: External downloads
06: External downloads
07: Downloads
08: External downloads
09: Downloads
10: External downloads
11: Home
12: Downloads
13: Downloads
14: Downloads
15: External downloads
16: External downloads
17: Downloads
18: External downloads
19: Home
20: Downloads
21: External downloads
22: Home
23: External downloads
24: External downloads
25: Downloads
26: External downloads
27: Downloads
28: External downloads
29: External downloads
30: Downloads
31: External downloads
32: Downloads
33: External downloads
34: Downloads
35: Home
36: Downloads
37: External downloads
38: Downloads
39: Downloads
40: External downloads
41: Downloads
42: My Account
43: Home
44: Downloads
45: Downloads
46: Home
47: Downloads
48: Downloads
49: Home
50: Home
51: External downloads
52: Downloads
53: Downloads
54: Downloads
55: External downloads
56: Downloads
57: Downloads
58: External downloads
59: Downloads
60: Home
61: Downloads
62: Downloads
63: Home
64: Downloads
65: Downloads
66: Downloads
67: Downloads
68: Home
69: Home
70: Downloads
71: Home
72: Downloads
73: Downloads
74: Downloads
75: Home
76: Downloads

Staff Online:

No staff members are online!
Downloads › Linear Accelerators

Main | Search | Add Download | New Downloads | Random

Sort: Title Ascending Descending   Published Ascending Descending   Updated Ascending Descending   Rating Ascending Descending  


Commissioning, calibration, and QA of linacs, IMRT, IGRT, treatment planning systems, etc.

 TG51 Calibration
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Wed May 26, 2010 4:14 pm
Download Now
TG-51 Calibration Workbook
Version 3.2.2
Submitted by: bkurko Homepage 0 reviews

 Varian High Energy Linac Replacement Part QA Guidelines
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Mon Jun 14, 2010 9:10 pm
Download Now
List of Varian recommended QA checks for high energy linacs to perform after replacement of various common parts.
Submitted by: zulloj Homepage 0 reviews

 Modified Winston-Lutz Test for IGRT Setups
Rating: Not rated Popularity: 4/5: Popular Updated: Wed Apr 13, 2011 6:32 pm
Download Now
Brief document describing the clinical implementation of a modified Winston-Lutz test. This test measures IGRT system end-to-end positioning accuracy with a precision of ~0.1 mm. It can be performed in less than 5 minutes.
Version 1.1
Submitted by: nathanchildress Homepage 0 reviews

 Pinnacle_Script_for_Naming_Beams
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Fri Oct 08, 2010 10:11 am
Download Now
This Pinnacle Script will rename a radiation beam based on the angle of incidence relative to the patient. The .txt extension on the file can be changed to .Script.
Submitted by: Choldsw Homepage 0 reviews

 Pinnacle_Script_for_Naming_All_Beams
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Fri Oct 08, 2010 10:12 am
Download Now
This Pinnacle Script is to be used with NameBeam.Script (Pinnacle_Script_for_Naming_Beams), and will change the name of all the radiation beams in one trial to reflect the angle of incidence relative to the patient.
Submitted by: Choldsw Homepage 0 reviews

 Varian DynaLog File Anonymizer
Rating: Not rated Popularity: 5/5: Very popular Updated: Wed Aug 10, 2011 6:59 am
Download Now
Program to automatically anonymize Varian DynaLog files.
Version 1.01
Submitted by: nathanchildress Homepage 0 reviews

 Patient Gantry Collision Check
No screenshot
Rating: Not rated Popularity: 1/5: Not popular Published: Mon Jul 23, 2012 12:57 pm
Download Now
A macro enabled excel spreadsheet to check for patient gantry collision when planning SBRTs or RapidArcs. Gantry and couch data was measured on a Varian Trilogy.
Version 1.0
Submitted by: Jigar Homepage 0 reviews

 Sample iComCAT files for NCS report 24
No screenshot
Rating: Not rated Popularity: 2/5: Slightly below average Published: Fri Oct 02, 2015 11:33 am
Download Now
A sample of a few iComCAT files used as part of VMAT commissioning for an Elekta VersaHD following NCS report 24.
Submitted by: rtphysicist Homepage 0 reviews

 Imager Position Calculator (Varian Linacs)
Rating: Not rated Popularity: 1/5: Not popular Published: Mon Oct 15, 2018 4:15 pm
Download Now
Calculates optimal imager panel positions for a Varian linear accelerator, based on field size, collimator rotation and vertical imager position.
Submitted by: anmcgrath Homepage 0 reviews

Page: Previous  1, 2

Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.
Interactive software released under GNU GPL, Code Credits, Privacy Policy