Mobius3D MobiusFX DoseLab TG-142 / DoseLab Pro MedPhys Files
MedPhys Files
   Login or Register
HomeDownloadsRegister
Downloads › Version History › Create 10 Subarcs from arc Version 2.1
Toggle Content Main Menu
 Home Members options Search
Toggle Content User Info

Welcome Anonymous

Nickname
Password

Membership:
Latest: Emcp
New Today: 0
New Yesterday: 0
Overall: 981

People Online:
Members: 0
Visitors: 35
Total: 35
Who Is Where:
 Visitors:
01: Downloads
02: External downloads
03: Downloads
04: Downloads
05: Downloads
06: Downloads
07: Downloads
08: Downloads
09: Downloads
10: Downloads
11: External downloads
12: Downloads
13: Downloads
14: External downloads
15: Downloads
16: Home
17: Downloads
18: Downloads
19: Downloads
20: External downloads
21: Downloads
22: Downloads
23: Downloads
24: Downloads
25: Downloads
26: Downloads
27: Downloads
28: Downloads
29: Downloads
30: External downloads
31: External downloads
32: External downloads
33: Downloads
34: External downloads
35: Downloads

Staff Online:

No staff members are online!
Create 10 Subarcs from arc Version 2.1
Main | Details | Download Now | History | Statistics

Version History
Track changes made to Create 10 Subarcs from arc Version 2.1 since its original version.

Version 2.1
Mon Jun 14, 2010 11:23 am by Joe64

Version 2 would create subarcs with an extra control point per subarc. Version 2.1 corrects this error. Although not a serious cause for concern in most cases, if the dose at the calc point was extremely low, this could cause the percent discrepency when calculating the mu to be high. I have seen great improvement when using version 2.1 for low doses.

Version Version 2.
Mon Jun 14, 2010 11:23 am by Joe64

Version 2 would create subarcs with an extra control point per subarc. Version 2.1 corrects this error. Although not a serious cause for concern in most cases, if the dose at the calc point was extremely low, this could cause the percent discrepency when calculating the mu to be high. I have seen great improvement when using version 2.1 for low doses.

Version Version 2.
Mon Jun 14, 2010 11:21 am by Joe64

Version 2 would create subarcs with an extra control point per subarc. Version 2.1 corrects this error. Although not a serious cause for concern in most cases, if the dose at the calc point was extremely low, this could cause the percent discrepency when calculating the mu to be high. I have seen great improvement when using version 2.1 for low doses.

Version Version 2.
Mon Jun 14, 2010 11:18 am by Joe64

Version 2 would create subarcs with an extra control point per subarc. Version 2.1 corrects this error. Although not a serious cause for concern in most cases, if the dose at the calc point was extremely low, this could cause the percent discrepency when calculating the mu to be high. I have seen great improvement when using version 2.1 for low doses.

Version V2
Tue May 25, 2010 11:20 pm by Joe64

Initial Version
Unless otherwise specified, all files are distributed under the MIT open source license for research and educational use only with no fitness guarantee.